The Latest Advancement in Ferromagnetic Detection for MRI Safety
FerrAlert™ SOLO is Installed in the controlled pre-screening zone. It is the highest sensitivity, full-body patient and personnel scanner available to MRI providers. FerrAlert™ detectors are recognized to be the most accurate ferromagnetic detectors for MRI due to their exclusive location-specificity feature. FerrAlert™ detectors have been independently tested to be the most sensitive in real-world MRI environments due to its unique and patented sensor technology.
Proprietary AMR Sensor Technology used in FerrAlert™ detectors proven to be most sensitive
in "Real World" MRI environment
Raw sensitivity is only meaningful if you are in the ocean looking for an isolated ferromagnetic object ( e.g. submarine). In such environment there are few other ferromagnetic, moving objects to interfere with sensing.
In the real environment of a hospital, where many ferromagnetic objects are moving all the time, you must be able to discriminate between "real" threats and objects that are ferromagnetic but not a threat.
FLUXGATE SENSOR DETECTION ZONE
KOPP PROPRIETARY AMR SENSOR DETECTION ZONE
PINPOINTS LOCATION
of the ferromagnetic threat allowing the Technologist to quickly and easily identify and remove it. NO invasive pat-down or hand-held detectors required.
INTELLIGENT VISUAL WARNING
is triggered by approaching ferrous objects
SELF-SCREENING
or supervised screening is consistent, unambiguous and simple
NO-TOUCH ACTIVATION
safeguards against dangerous cross-contamination
PATENTED TECHNOLOGY
suppresses false alarms and warnings while providing the highest sensitivity to ferromagnetic threats. The use of 12 sensors ensures uniform sensitivity and detection reliability from head to toe.
For a list of international patents: click here
REDUCES ALARM FATIGUE
by not producing acoustic alarm unles the presence of human body is detected (body heat sensor)
Dimensions:
Height 86 ¼” (220 cm), Depth 2 ½” (6.5 cm), Width 2” (5 cm)
Complies with ES60601-1-8 International Standards for Medical Device Alarms
Complies with IEC 60601-1:2005 Medical Device Specification Requirements
Medical Power Supply:
100 to 240 VAC, 47 to 63 Hz, 42 Watts
Continuous Magnetic Disturbance Monitoring provides instant feedback via integrated and highly visible bar graphs
Safe Passive Detection
NO electromagnetic radiation, RF radiation, or magnetic field
Adjustable Sensitivity and Audio Alarm Levels
Confirms to ALL Applicable Recommendations and Standards including FDA, ACR AAMI, Joint Commission, FGI and VA
Comprehensive Self-Test Function for hospital periodic maintenance, as well as piece of mind
Integrates esasily into any established screening procedures. Elegant, small footprint installation
Inexpensive - affordable for all MRI facilities
FerrAlert™Approved Patient Transport Equipment will not trigger an alarm
Ambient Magnetic Disturbance Indicator: Eight (8) blue bars
Sensitivity: Adjustable
Audio Alarm: Selectable, adjustable volume
Mounting: Wall or free-standing with optional basel
Battery Operation:
Optional